Identificador persistente para citar o vincular este elemento:
http://hdl.handle.net/10662/11412
Registro completo de Metadatos
Campo DC | Valor | idioma |
---|---|---|
dc.contributor.author | Mazoteras Pardo, Victoria | - |
dc.contributor.author | Becerro de Bengoa Vallejo, Ricardo | - |
dc.contributor.author | Losa Iglesias, Marta Elena | - |
dc.contributor.author | López López, Daniel | - |
dc.contributor.author | Palomo López, Patricia | - |
dc.contributor.author | Rodríguez Sanz, David | - |
dc.contributor.author | Calvo Lobo, César | - |
dc.date.accessioned | 2020-10-02T07:58:31Z | - |
dc.date.available | 2020-10-02T07:58:31Z | - |
dc.date.issued | 2018 | - |
dc.identifier.issn | 2291-5222 | - |
dc.identifier.uri | http://hdl.handle.net/10662/11412 | - |
dc.description.abstract | FUNDAMENTOS: La obesidad y la hipertensión arterial (HBP) suponen un alto riesgo cardiovascular, y son causas frecuentes de enfermedades cardiovasculares. OBJETIVO: El objetivo de este estudio fue validar la aplicación móvil QardioArm para el control de la presión arterial alta en sujetos obesos (índice de masa corporal ≥30 kg/m2) según las directrices de la Sociedad Europea de Hipertensión-Protocolo Internacional 2 (ESH-IP2). MÉTODOS: Reclutamos 33 sujetos obesos y medimos su presión sanguínea usando QardioArm (dispositivo de prueba) y Omron M3 Intellisense (Omron Healthcare, Kyoto, Japón; dispositivo estándar). Comparamos la presión sanguínea sistólica (PAS), la presión sanguínea diastólica (PAD) y la frecuencia cardíaca (FC) según el ESH-IP2. RESULTADOS: Un total de 95 de 99 diferencias para la PAS y 91 de 99 para la PAD mostraron diferencias absolutas dentro de los 10 mm Hg. Un total de 98 de 99 diferencias para la PAS y 98 de 99 para la PAD mostraron diferencias absolutas dentro de 15 mm Hg. Este resultado satisfizo los requisitos de la parte 1 del ESH-IP2. Un total de 27 de 33 individuos para la PAS y 30 de 33 individuos para la PAD tuvieron un mínimo de 2 de 3 comparaciones dentro de la diferencia de 5 mm Hg. Ninguno de los sujetos tuvo 3 diferencias fuera de 5 mm Hg para SBP y DBP, satisfaciendo la parte 2 del ESH-IP2. Para las mediciones de HR, un total de 90 de 99 diferencias tuvieron diferencias absolutas dentro de 3 pulsaciones por minuto (bpm), y un total de 94 o 99 diferencias tuvieron diferencias absolutas dentro de 5 bpm. Un total de 98 de 99 diferencias tuvieron diferencias absolutas dentro de 8 bpm. Por lo tanto, el dispositivo de prueba satisfizo la parte 1 de los criterios del ESH-IP2 para el HR. Para la parte 2 del ESH-IP2, 31 de 33 individuos tuvieron un mínimo de 2 de 3 comparaciones dentro de 3 bpm de diferencia para el CRI. Sólo 1 de 33 sujetos tuvo 3 diferencias fuera de 3 bpm. CONCLUSIONES: Hasta donde sabemos, este fue el primer estudio en mostrar que una aplicación que mide la presión sanguínea y el HR cumple con los requerimientos del ESH-IP2 en una población obesa. Creemos que el ESH-IP2 debería publicar criterios explícitos para la validación de dispositivos de presión sanguínea en poblaciones específicas. | es_ES |
dc.description.abstract | BACKGROUND: Obesity and high blood pressure (HBP) pose high cardiovascular risks, and they are frequent causes of cardiovascular disease. OBJECTIVE: The aim of this study was to validate the mobile app QardioArm for high blood pressure monitoring in obese subjects (body mass index ≥30 kg/m2) according to guidelines in the European Society of Hypertension-International Protocol 2 (ESH-IP2). METHODS: We recruited 33 obese subjects and measured their blood pressure using QardioArm (test device) and Omron M3 Intellisense (Omron Healthcare, Kyoto, Japan; standard device). We compared systolic blood pressure (SBP), diastolic blood pressure (DBP), and heart rate (HR) according to the ESH-IP2. RESULTS: A total of 95 of 99 differences for SBP and 91 of 99 for DBP displayed absolute differences within 10 mm Hg. A total of 98 of 99 differences for SBP and 98 of 99 for DBP exhibited absolute differences within 15 mm Hg. This result satisfied requirements for part 1 of the ESH-IP2. A total of 27 out of 33 individuals for SBP and 30 out of 33 individuals for DBP had a minimum of 2 of 3 comparisons within 5 mm Hg difference. None of the subjects had 3 differences outside 5 mm Hg for SBP and DBP, satisfying part 2 of the ESH-IP2. For HR measurements, a total of 90 of 99 differences had absolute differences within 3 beats per minute (bpm), and a total of 94 or 99 differences had absolute differences within 5 bpm. A total of 98 of 99 differences had absolute differences within 8 bpm. Therefore, the test device satisfied part 1 of ESH-IP2 criteria for HR. For part 2 of ESH-IP2, 31 of 33 individuals had a minimum of 2 of 3 comparisons within 3 bpm difference for HR. Only 1 of 33 subjects had 3 differences outside 3 bpm. CONCLUSIONS: To the best of our knowledge, this was the first study to show that an app that measures blood pressure and HR meets the requirements of the ESH-IP2 in an obese population. We believe the ESH-IP2 should publish explicit criteria for validation of blood pressure devices in specific populations. | es_ES |
dc.format.extent | 10 p. | es_ES |
dc.format.mimetype | application/pdf | en_US |
dc.language.iso | eng | es_ES |
dc.publisher | JMIR | es_ES |
dc.rights | Atribución 4.0 Internacional | * |
dc.rights.uri | http://creativecommons.org/licenses/by/4.0/ | * |
dc.subject | Obesidad | es_ES |
dc.subject | Determinación de la presión arterial | es_ES |
dc.subject | Obesity | es_ES |
dc.subject | Blood pressure determination | es_ES |
dc.title | The QardioArm blood pressure app for self-measurement in an obese population: Validation study using the European Society of Hypertension International Protocol revision 2010 | es_ES |
dc.type | article | es_ES |
dc.description.version | peerReviewed | es_ES |
europeana.type | TEXT | en_US |
dc.rights.accessRights | openAccess | es_ES |
dc.subject.unesco | 3205 Medicina Interna | es_ES |
dc.subject.unesco | 32 Ciencias Médicas | es_ES |
europeana.dataProvider | Universidad de Extremadura. España | es_ES |
dc.identifier.bibliographicCitation | Mazoteras-Pardo V, Becerro-De-Bengoa-Vallejo R, Losa-Iglesias ME, López-López D, Palomo-López P, Rodríguez-Sanz D, Calvo-Lobo C. The QardioArm Blood Pressure App for Self-Measurement in an Obese Population: Validation Study Using the European Society of Hypertension International Protocol Revision 2010. JMIR Mhealth Uhealth 2018;6(10):e11632. DOI: 10.2196/11632 | es_ES |
dc.type.version | publishedVersion | es_ES |
dc.contributor.affiliation | Universidad Complutense de Madrid | es_ES |
dc.contributor.affiliation | Universidad de Extremadura. Departamento de Enfermería | es_ES |
dc.contributor.affiliation | Universidad Rey Juan Carlos | - |
dc.contributor.affiliation | Universidade da Coruña | - |
dc.contributor.affiliation | Universidad Europea de Madrid | - |
dc.contributor.affiliation | Universidad de León | - |
dc.relation.publisherversion | https://mhealth.jmir.org/2018/10/e11632 | es_ES |
dc.relation.publisherversion | https://doi.org/10.2196/11632 | es_ES |
dc.identifier.doi | 10.2196/11632 | - |
dc.identifier.publicationtitle | JMIR Mhealth Uhealth | es_ES |
dc.identifier.publicationissue | 10 | es_ES |
dc.identifier.publicationfirstpage | 1 | es_ES |
dc.identifier.publicationlastpage | 10 | es_ES |
dc.identifier.publicationvolume | 6, e11632 | es_ES |
Colección: | DENFE - Artículos |
Este elemento está sujeto a una licencia Licencia Creative Commons