Identificador persistente para citar o vincular este elemento: http://hdl.handle.net/10662/19660
Registro completo de Metadatos
Campo DCValoridioma
dc.contributor.authorBaeza, Antonio (Antonio Salvador)-
dc.contributor.authorCaballero Andrada, José Manuel-
dc.contributor.authorCorbacho Merino, José Ángel-
dc.contributor.authorOntalba Salamanca, María Ángeles-
dc.contributor.authorVasco, José-
dc.date.accessioned2024-02-01T12:40:16Z-
dc.date.available2024-02-01T12:40:16Z-
dc.date.issued2014-
dc.identifier.issn0952-4746-
dc.identifier.urihttp://hdl.handle.net/10662/19660-
dc.description.abstractThe main objective of automatic environmental radiation warning networks is to quantify a set of radiological parameters corresponding to the medium being monitored (water, air, etc) in the shortest possible time so as to be able to provide rapid and precise information on the medium's radiological status, and on any alterations that may occur and their severity. Specifically, in this paper we present the substantial improvements that have been carried out in an automatic near-real-time radiation monitoring of a water system belonging to Radiation Alert Network of Extremadura (RARE) in southwest Spain. These improvements are based on the incorporation of (i) a gamma spectrometry system with solid scintillation detectors and compact digital electronics, (ii) continuous measurement of the water flow that is being monitored, (iii) improvements in the maintenance tasks required to optimise the operation of this type of equipment and (iv) the controlled and automated collection of water samples so that, in the case of a possible radiological anomaly, it will be possible to perform ulterior specific complementary determinations in a low-background laboratoryes_ES
dc.description.abstractEl objetivo principal de las redes automáticas de alerta radiológica ambiental es cuantificar un conjunto de parámetros radiológicos correspondientes al medio monitorizado (agua, aire, etc.) en el menor tiempo posible para poder proporcionar información rápida y precisa sobre el estado radiológico del medio, así como sobre las alteraciones que se puedan producir y su gravedad. En concreto, en este trabajo se presentan las mejoras sustanciales que se han llevado a cabo en una monitorización radiológica automática en tiempo casi real de un sistema de agua perteneciente a la Red de Alerta Radiológica de Extremadura (RARE) en el suroeste de España. Estas mejoras se basan en la incorporación de (i) un sistema de espectrometría gamma con detectores de centelleo sólido y electrónica digital compacta, (ii) la medida en continuo del caudal de agua que se está monitorizando, (iii) mejoras en las tareas de mantenimiento necesarias para optimizar el funcionamiento de este tipo de equipos y (iv) la recogida controlada y automatizada de muestras de agua para que, ante una posible anomalía radiológica, sea posible realizar posteriores determinaciones complementarias específicas en un laboratorio de bajo fondo.es_ES
dc.description.sponsorshipThis work was made possible thanks, firstly, to funding from Spain’s Nuclear Safety Council and the Government of Extremadura, through the Collaboration Agreement for the ‘Operation, Management, and Access to Data of the Automatic Environmental Radiation Monitoring Stations’, and, secondly, to funding received by the LARUEX (FQM001) research group from the Government of Extremadura in its IV Regional R&D + i Plan, DOE No 250 of 30.12.2010.es_ES
dc.format.extent13 p.es_ES
dc.format.mimetypeapplication/pdfen_US
dc.language.isoenges_ES
dc.publisherIOP Sciencees_ES
dc.subjectMonitor de radiación en aguases_ES
dc.subjectWater radiation monitoringes_ES
dc.subjectVigilanciaes_ES
dc.subjectSurveillancees_ES
dc.subjectEspectrometría gammaes_ES
dc.subjectGamma spectrometryes_ES
dc.subjectMedidas en tiempo reales_ES
dc.subjectReal time measurementses_ES
dc.titleProposed improvements to existing water monitoring systems in automatic radiological warning networkses_ES
dc.typearticlees_ES
dc.description.versionpeerReviewedes_ES
europeana.typeTEXTen_US
dc.rights.accessRightsclosedAccesses_ES
dc.subject.unesco2207 Física Atómica y Nucleares_ES
europeana.dataProviderUniversidad de Extremadura. Españaes_ES
dc.identifier.bibliographicCitationBaeza, A., Caballero, J. M., Corbacho, J. Á., Salamanca, M. Á. O., & Vasco, J. (2014). Proposed improvements to existing water monitoring systems in automatic radiological warning networks. Journal of Radiological Protection, 34(2), 313. doi:10.1088/0952-4746/34/2/313es_ES
dc.type.versionpublishedVersiones_ES
dc.contributor.affiliationUniversidad de Extremadura. Departamento de Física Aplicadaes_ES
dc.relation.publisherversionhttps://iopscience.iop.org/article/10.1088/0952-4746/34/2/313es_ES
dc.identifier.doi10.1088/0952-4746/34/2/313-
dc.identifier.publicationtitleJournal of Radiological Protectiones_ES
dc.identifier.publicationissue2-
dc.identifier.publicationfirstpage313es_ES
dc.identifier.publicationlastpage324es_ES
dc.identifier.publicationvolume34es_ES
dc.identifier.e-issn1361-6498-
dc.identifier.orcid0000-0001-9018-8083es_ES
dc.identifier.orcid0000-0002-2648-2867es_ES
dc.identifier.orcid0000-0002-9677-4777es_ES
Colección:DFIAP - Artículos

Archivos
Archivo Descripción TamañoFormato 
0952_4746_34_2_313.pdf
???org.dspace.app.webui.jsptag.ItemTag.accessRestricted???
777,85 kBAdobe PDFDescargar    Pide una copia


Este elemento está sujeto a una licencia Licencia Creative Commons Creative Commons