Identificador persistente para citar o vincular este elemento: http://hdl.handle.net/10662/4701
Registro completo de Metadatos
Campo DCValoridioma
dc.contributor.advisorCancillo Fernández, María Luisa-
dc.contributor.authorÁlvarez Piedehierro, Ana-
dc.contributor.otherUniversidad de Extremadura. Departamento de Físicaes_ES
dc.date.accessioned2016-09-30T08:25:59Z-
dc.date.available2016-09-30T08:25:59Z-
dc.date.issued2016-09-30-
dc.date.submitted2016-07-15-
dc.identifier.urihttp://hdl.handle.net/10662/4701-
dc.descriptionTesis doctoral con la Mención de "Doctor Internacional"es_ES
dc.description.abstractEsta Tesis Doctoral se centra en el estudio de la radiación ultravioleta obtenida mediante radiómetros multicanal modelo NILU-UV. Este tipo de instrumentos es muy versátil ya que a partir de sus medidas pueden obtenerse diversos productos radiométricos y la cantidad total de ozono en columna. La metodología de calibración y obtención de productos con este tipo de medidas es un tema abierto. Por ello, en esta tesis se han comparado diversas metodologías existentes y se han realizado nuevas propuestas y modificaciones en los diferentes pasos del proceso de calibración para mejorar el comportamiento de la irradiancia calibrada, especialmente en el intervalo de ángulos cenitales elevados. Otro aspecto de gran interés en este tipo de instrumentos es la correcta caracterización de la deriva de los coeficientes de calibración, por ello, se ha realizado un seguimiento de la sensibilidad absoluta de dos instrumentos NILU-UV mediante calibraciones relativas y comparación con espectrorradiómetros de referencia durante el periodo de estudio (2011-2015) y se ha propuesto una metodología para la aplicación de la calibración a largo plazo. En relación a los productos que pueden derivarse de las medidas de irradiancia calibrada de los radiómetros NILU-UV, se ha analizado cómo obtener el par óptimo con el que determinar el ozono en columna y se ha estimado esta magnitud con los dos instrumentos multicanal. Finalmente, mediante combinación lineal de las irradiancias de los canales, se ha estimado la irradiancia eritemática para el mismo periodo. Ambos productos se han comparado con valores de referencia.es_ES
dc.description.abstractThis thesis focuses in the ultraviolet radiation as measured by NILU-UV multifilter instruments. NILU-UV instruments are very versatile since from their measurements can be derived various products such as ultraviolet dose rates or the total ozone column. Calibration and product retrieval methodologies are still under development and there is a need for standardizing these protocols. Within this framework, in this work several existent methodologies were compared and new procedures were proposed in every step of the calibration/product retrieval process. The absolute sensitivity of two NILU-UV instruments was tracked for the period 2011-2015, using relative calibrations and by intercomparison with spectroradiometers. Several calibration equations have been analyzed and improvements have been made to them in order to enhance the performance of the equations in the high solar zenith angle range and for long-term application. Regarding the product retrieval from NILU-UV measurements, once the best pair of channels was selected for deriving ozone, it was estimated for a two-year period with both instruments. Finally, by means of a linear combination of the measurements of NILU-UV instruments, erythemally weighted irradiance was obtained for the same period of time. Both data products were compared with reference values.es_ES
dc.description.sponsorshipGobierno de Extremadura, Consejería de Empleo, Empresa e Innovación y Fondo Social Europeo: beca predoctoral (PD10110). Ayuda a Grupos GR15137. Ministerio de Ciencia e Innovación, proyecto CGL2008-05939-C03-02. Ministerio de Economía y Competitividad, proyectos CGL2011-29921-C02-01 y CGL2014-56255-C2-1-Res_ES
dc.format.extent293 p.es_ES
dc.format.mimetypeapplication/pdfen_US
dc.language.isospaes_ES
dc.rightsAtribución-NoComercial-SinDerivadas 3.0 España*
dc.rights.urihttp://creativecommons.org/licenses/by-nc-nd/3.0/es/*
dc.subjectRadiación solar ultravioletaes_ES
dc.subjectOzonoes_ES
dc.subjectRadiómetro multicanales_ES
dc.subjectSolar ultraviolet radiationes_ES
dc.subjectOzonees_ES
dc.subjectMultifilter radiometeres_ES
dc.titleMedida y modelización de la radiación ultravioleta mediante el uso de radiómetros multicanales_ES
dc.typedoctoralThesises_ES
europeana.typeTEXTen_US
dc.rights.accessRightsopenAccesses_ES
dc.subject.unesco2501 Ciencias de la Atmósferaes_ES
dc.subject.unesco2509 Meteorologíaes_ES
dc.subject.unesco2209.23 Radiación Visiblees_ES
europeana.dataProviderUniversidad de Extremadura. Españaes_ES
dc.identifier.orcid0000-0002-1900-8139-
dc.identifier.orcid0000-0002-0438-3526-
Colección:Tesis doctorales

Archivos
Archivo Descripción TamañoFormato 
TDUEX_2016_Alvarez_Piedehierro.pdf38,15 MBAdobe PDFDescargar


Este elemento está sujeto a una licencia Licencia Creative Commons Creative Commons