Improving short term instability for quantitative analyses with portable electronic noses

Show simple item record

dc.contributor.author Macías Macías, Miguel
dc.contributor.author Enrique Agudo, José
dc.contributor.author García Manso, Antonio
dc.contributor.author García Orellana, Carlos Javier
dc.contributor.author González Velasco, Horacio Manuel
dc.contributor.author Gallardo Caballero, Ramón
dc.date.accessioned 2017-01-19T11:52:32Z
dc.date.available 2017-01-19T11:52:32Z
dc.date.issued 2014
dc.identifier.issn 1424-8220
dc.identifier.uri http://hdl.handle.net/10662/5133
dc.description.abstract Uno de los principales problemas al trabajar con narices electrónicas es la falta de reproducibilidad o repetibilidad de la respuesta del sensor, de modo que, si este problema no se considera correctamente, las narices electrónicas pueden ser inútiles, especialmente para análisis cuantitativos. Por otro lado, la irreproductibilidad se incrementa con narices electrónicas portátiles y de bajo costo donde no se puede usar equipo de laboratorio como generadores de gas cero. En este trabajo se estudia la reproducibilidad de dos narices electrónicas portátiles, la PEN3 (comercial) y CAPINose (un diseño patentado) mediante el uso de muestras de vino sintético. Mostramos que en ambos casos la inestabilidad a corto plazo asociada a la respuesta de los sensores a la misma muestra y bajo las mismas condiciones representa un problema mayor y proponemos una técnica de normalización interna que, en ambos casos, reduce la variabilidad de la respuesta de los sensores. Finalmente, se muestra que la normalización propuesta parece ser más eficaz en el caso de CAPINose, reduciendo, por ejemplo, la variabilidad asociada al sensor TGS2602 de 12.19% a 2.2%. es_ES
dc.description.abstract One of the main problems when working with electronic noses is the lack of reproducibility or repeatability of the sensor response, so that, if this problem is not properly considered, electronic noses can be useless, especially for quantitative analyses. On the other hand, irreproducibility is increased with portable and low cost electronic noses where laboratory equipment like gas zero generators cannot be used. In this work, we study the reproducibility of two portable electronic noses, the PEN3 (commercial) and CAPINose (a proprietary design) by using synthetic wine samples. We show that in both cases short term instability associated to the sensors’ response to the same sample and under the same conditions represents a major problem and we propose an internal normalization technique that, in both cases, reduces the variability of the sensors’ response. Finally, we show that the normalization proposed seems to be more effective in the CAPINose case, reducing, for example, the variability associated to the TGS2602 sensor from 12.19% to 2.2%. es_ES
dc.description.sponsorship Trabajo patrocinado parcialmente por la Junta de Extremadura y Fondos FEDER: Proyectos PDT09A005 y GR10018 es_ES
dc.format.extent 13 p. es_ES
dc.language.iso eng es_ES
dc.publisher MDPI es_ES
dc.rights Atribución-NoComercial-SinDerivadas 3.0 España *
dc.rights.uri http://creativecommons.org/licenses/by-nc-nd/3.0/es/ *
dc.subject Nariz electrónica es_ES
dc.subject Análisis cuantitativo es_ES
dc.subject Sensor de gas es_ES
dc.subject Electronic nose es_ES
dc.subject Quantitative analysis es_ES
dc.subject Gas sensor es_ES
dc.title Improving short term instability for quantitative analyses with portable electronic noses es_ES
dc.type article es_ES
dc.description.version peerReviewed es_ES
dc.rights.accessRights openAccess es_ES
dc.subject.unesco 3307 Tecnología Electrónica es_ES
dc.identifier.bibliographicCitation Macías Macías, M.; Enrique Agudo, J.; García Manso, A.; García Orellana, C. J.; González Velasco, H. M. y Gallardo Caballero, R. (2014). Improving short term instability for quantitative analyses with portable electronic noses. Sensors, 14 (6), 10514-10526. ISSN 1424-8220 es_ES
dc.type.version publishedVersion es_ES
dc.contributor.affiliation Universidad de Extremadura. Departamento de Ingeniería Eléctrica, Electrónica y Automática es_ES
dc.relation.publisherversion http://www.mdpi.com/1424-8220/14/6/10514/htm es_ES
dc.identifier.doi 10.3390/s140610514
dc.identifier.publicationtitle Sensors es_ES
dc.identifier.publicationissue 6 es_ES
dc.identifier.publicationfirstpage 10514 es_ES
dc.identifier.publicationlastpage 10526 es_ES
dc.identifier.publicationvolume 14 es_ES


Files in this item

Files Size Format View
s140610514.pdf 934.1Kb PDF Thumbnail

The following license files are associated with this item:

This item appears in the following Collection(s)

Show simple item record

Atribución-NoComercial-SinDerivadas 3.0 España Except where otherwise noted, this item's license is described as Atribución-NoComercial-SinDerivadas 3.0 España

Search DSpace


Browse

My Account

Statistics

Help

Redes sociales