Retrieval of the aerosol optical thickness from UV global irradiance measurements

DSpace/Manakin Repository

español português english

Retrieval of the aerosol optical thickness from UV global irradiance measurements

Show full item record

Title: Retrieval of the aerosol optical thickness from UV global irradiance measurements
Author: Costa, Maria João Tavares da; Salgueiro, Vanda Cristina Pires; Bortoli, Daniele; Obregón Muñoz, María Ángeles; Antón Martínez, Manuel; Silva, Ana Maria Almeida
Abstract: La irradiación UV se mide en Évora desde hace varios años, donde también se encuentra un fotómetro solar CIMEL integrado en AERONET. En el presente trabajo, las mediciones de las irradiaciones UVA (315 - 400 Nm) tomadas con radiómetros Kipp & Zonen, así como los datos de satélite de los valores totales de la columna de ozono, se utilizan en combinación con cálculos de transferencia radiactiva para estimar el espesor óptico de aerosol (AOT) de UV. El AOT de UV obtenido en Évora se compara con AERONET AOT (340 y 380 Nm) y se encuentra una buena concordancia con un error cuadrático medio de 0,05 (error cuadrático medio normalizado de 8,3%) y un error absoluto medio de 0,04 (porcentaje de error medio del 2,9%). La metodología que se utiliza para estimar el AOT de UV en Sines, un sitio industrializado en la costa occidental del Atlántico, donde la irradiación UV es monitorizada desde 2013, pero no hay información disponible en aerosol.The UV irradiance is measured at Évora since several years, where a CIMEL sunphotometer integrated in AERONET is also installed. In the present work, measurements of UVA (315 - 400 Nm) irradiances taken with Kipp&Zonen radiometers, as well as satellite data of ozone total column values, are used in combination with radiative transfer calculations, to estimate the aerosol optical thickness (AOT) in the UV. The retrieved UV AOT in Évora is compared with AERONET AOT (at 340 and 380 Nm) and a fairly good agreement is found with a root mean square error of 0.05 (normalized root mean square error of 8.3%) and a mean absolute error of 0.04 (mean percentage error of 2.9 %). The methodology is then used to estimate the UV AOT in Sines, an industrialized site on the Atlantic western coast, where the UV irradiance is monitored since 2013 but no aerosol information is available.
URI: http://hdl.handle.net/10662/5231
Date: 2015


Files in this item

Files Size Format View
1755-1315_28_1_012007.pdf 982.5Kb PDF Thumbnail

The following license files are associated with this item:

This item appears in the following Collection(s)

Show full item record

Atribución-NoComercial-CompartirIgual 3.0 España Except where otherwise noted, this item's license is described as Atribución-NoComercial-CompartirIgual 3.0 España

Search DSpace


Browse

My Account

Statistics

Help

Redes sociales