Identificador persistente para citar o vincular este elemento: http://hdl.handle.net/10662/6169
Registro completo de Metadatos
Campo DCValoridioma
dc.contributor.advisorSánchez Quintana, Damián-
dc.contributor.advisorGañán Presmanes, Yolanda-
dc.contributor.advisorMacías Rodríguez, Domingo-
dc.contributor.authorMacías Gañán, Yolanda-
dc.contributor.otherUniversidad de Extremadura. Departamento de Anatomía, Biología Celular y Zoologíaes_ES
dc.date.accessioned2017-09-14T08:16:56Z-
dc.date.available2017-09-14T08:16:56Z-
dc.date.issued2017-09-14-
dc.date.submitted2017-07-10-
dc.identifier.urihttp://hdl.handle.net/10662/6169-
dc.description.abstractEl implante valvular aórtico transcatéter es el tratamiento de elección en pacientes con estenosis aórtica inoperables. Debido a la estrecha relación anatómica existente entre el sistema de conducción auriculoventricular y la válvula aórtica, la expansión de una prótesis valvular contra el aparato valvular aórtico, puede conducir a la aparición de alteraciones de la conducción, pudiendo resultar en bloqueo cardiaco parcial o completo y la necesidad de implantar un marcapasos permanente. Existen algunas variantes en las que el sistema de conducción se encuentra expuesto, siendo susceptible a lesiones, como: la variable posición del nodo auriculoventricular y el haz de His, la longitud del septum membranoso, la presencia de calcificaciones en los velos aórticos, el grosor del septum interventricular y la profundidad de la prótesis. En nuestro trabajo hemos estudiado 57 corazones con técnicas macroscópicas y de microscopía óptica, observando dichas variaciones y encontrando posible riesgo de lesión durante la implantación de la válvula percutánea debido a: un septum membranoso más corto en longitud en el 17,5% de los casos; una desviación hacia el lado izquierdo de la división del haz de His en 22 corazones; 10 corazones poseen un septum membranoso con un espesor ≥11 mm, a 6 mm de la cresta del septum muscular interventricular; la presencia de calcificaciones en el cuerpo fibroso central, septum membranoso y seno no coronario de la válvula aórtica en el 47% de los casos; y una fragmentación del nodo auriculoventricular en islotes de tejido de conducción en el 9% de los casos.es_ES
dc.description.abstractTranscatheter aortic valve implantation is the chosen treatment in inoperable patients with aortic stenosis. Due to the close anatomical relation between the atrioventricular conduction system and the aortic valve, the expansion of a valvular prosthesis against the aortic valve may lead to conduction abnormalities, resulting in partial or complete heart block and the need to implant a permanent pacemaker. There are some variants in which the conduction system is exposed, being susceptible to injuries, such as: the variable position of the atrioventricular node and the His bundle, the membranous septum length, the presence of calcifications in the aortic leaflets, the interventricular septum thickness and the prosthesis depth. In our research, we studied 57 hearts with macroscopic and optical microscopy techniques, observing these variations and finding possible risk of injury during percutaneous valve implantation due to: a shorter membranous septum in length in 17.5% of the cases; a deviation toward the left side of the division of the His bundle in 22 hearts; 10 hearts have a membranous septum with a thickness ≥11 mm, 6 mm from the crest of the muscular interventricular septum; the presence of calcifications in the central fibrous body, membranous septum and non-coronary sinus of the aortic valve in 47% of the cases; and a fragmentation of the atrioventricular node in islands of conduction tissue in 9% of the cases.es_ES
dc.format.extent161 p.es_ES
dc.format.mimetypeapplication/pdfen_US
dc.language.isospaes_ES
dc.rightsAtribución-NoComercial-SinDerivadas 3.0 España*
dc.rights.urihttp://creativecommons.org/licenses/by-nc-nd/3.0/es/*
dc.subjectImplante valvular aórtico transcatéteres_ES
dc.subjectEstenosis aórticaes_ES
dc.subjectTejido de conducción cardiacoes_ES
dc.subjectTranscatheter aortic valve implantationes_ES
dc.subjectAortic stenosises_ES
dc.subjectCardiac conduction tissuees_ES
dc.titleAnálisis de los factores anatómicos que pueden determinar que se afecte el sistema de conducción AV durante el reemplazo transcatéter de la válvula aórticaes_ES
dc.typedoctoralThesises_ES
europeana.typeTEXTen_US
dc.rights.accessRightsopenAccesses_ES
dc.subject.unesco3205.01 Cardiologíaes_ES
dc.subject.unesco3207.04 Patología Cardiovasculares_ES
dc.subject.unesco3213.07 Cirugía del Corazónes_ES
europeana.dataProviderUniversidad de Extremadura. Españaes_ES
dc.identifier.orcid0000-0001-7528-9169-
dc.identifier.orcid0000-0001-9176-2964-
dc.identifier.orcid0000-0002-6714-5322-
Colección:DABCZ - Tesis doctorales
Tesis doctorales

Archivos
Archivo Descripción TamañoFormato 
TDUEX_2017_Macias_Gañan.pdf78,71 MBAdobe PDFDescargar


Este elemento está sujeto a una licencia Licencia Creative Commons Creative Commons