Quality assessment of solar UV irradiance measured with array spectroradiometers

DSpace/Manakin Repository

español português english

Quality assessment of solar UV irradiance measured with array spectroradiometers

Show simple item record

dc.contributor.author Egli, Luca
dc.contributor.author Gröbner, Julian
dc.contributor.author Hülsen, Gregor
dc.contributor.author Bachmann, Luciano
dc.contributor.author Blumthaler, Mario
dc.contributor.author Dubard, Jimmy
dc.contributor.author Khazova, Marina
dc.contributor.author Kift, Richard
dc.contributor.author Hoogendijk, Kees
dc.contributor.author Serrano Pérez, Antonio
dc.contributor.author Smedley, Andrew
dc.contributor.author Vilaplana Guerrero, José Manuel
dc.date.accessioned 2018-05-22T11:11:03Z
dc.date.available 2018-05-22T11:11:03Z
dc.date.issued 2016
dc.identifier.issn 1867-1381
dc.identifier.uri http://hdl.handle.net/10662/7455
dc.description.abstract La cuantificación fiable de la radiación ultravioleta (UV) en la superficie de la tierra requiere mediciones precisas de la radiación UV solar espectral global con el fin de determinar la exposición UV a la piel humana y comprender las tendencias a largo plazo en este parámetro. Los espectrorradiómetros de matriz (ASRM) son instrumentos pequeños, livianos, robustos y rentables, y se utilizan cada vez más para mediciones de irradiancia espectral. Dentro del proyecto europeo EMRP ENV03 "Solar UV", se han desarrollado nuevos dispositivos, directrices y métodos de caracterización para mejorar las mediciones de UV solar con ASRM, y se ha brindado asistencia a la comunidad de usuarios finales. Para evaluar la calidad de 14 ASRM de usuario final, se llevó a cabo una intercomparación UV solar en la plataforma de medición del World Radiation Center (PMOD/WRC) en Davos, Suiza, del 10 al 17 de julio de 2014. Los resultados de la comparación ciega reveló que los ASRM, actualmente utilizados para las mediciones de UV solar, muestran una gran variación en la calidad de sus mediciones de UV solar. La mayoría de los instrumentos sobreestiman el índice UV ponderado de eritema, en particular a grandes ángulos de zenit solar, debido a la contribución de luz dispersa en el rango de UV-B. El análisis espectral de la irradiación UV solar global apoyó aún más el hallazgo de que las incertidumbres en el rango UV-B son muy grandes debido a la contribución de la luz dispersa en este rango de longitud de onda. En resumen, el índice de UV puede ser detectado por algunos ASRMs disponibles comercialmente dentro del 5% en comparación con el espectrorradiómetro de referencia mundial, si está bien caracterizado y calibrado, pero solo para un rango limitado de ángulos de zenit solar. En general, los instrumentos probados todavía no son adecuados para las mediciones de UV solar para todo el rango entre 290 y 400 nm en todas las condiciones atmosféricas. es_ES
dc.description.abstract The reliable quantification of ultraviolet (UV) radiation at the earth’s surface requires accurate measurements of spectral global solar UV irradiance in order to determine the UV exposure to human skin and to understand long-term trends in this parameter. Array spectroradiometers (ASRMs) are small, light, robust and cost-effective instruments, and are increasingly used for spectral irradiance measurements. Within the European EMRP ENV03 project “Solar UV”, new devices, guidelines and characterization methods have been developed to improve solar UV measurements with ASRMs, and support to the end user community has been provided. In order to assess the quality of 14 end user ASRMs, a solar UV inter-comparison was held on the measurement platform of the World Radiation Center (PMOD/WRC) in Davos, Switzerland, from 10 to 17 July 2014. The results of the blind inter-comparison revealed that ASRMs, currently used for solar UV measurements, show a large variation in the quality of their solar UV measurements. Most of the instruments overestimate the erythema-weighted UV index – in particular at large solar zenith angles – due to stray light contribution in the UV-B range. The spectral analysis of global solar UV irradiance further supported the finding that the uncertainties in the UV-B range are very lar e due to stray light contribution in this wavelength range. In summary, the UV index may be detected by some commercially available ASRMs within 5% compared to the world reference spectroradiometer, if well characterized and calibrated, but only for a limited range of solar zenith angles. Generally, the tested instruments are not yet suitable for solar UV measurements for the entire range between 290 and 400 nm under all atmospheric conditions. es_ES
dc.description.sponsorship • EURAMET y Unión Europea. Proyectos EMRP ENV03 “Traceability for surface spectral solar ultraviolet radiation” • Ministerio de Economía y Competitividad. Proyectos de investigación CGL2011-29921-C02 y CGL2014-56255-C2 es_ES
dc.format.extent 15 p. es_ES
dc.format.mimetype application/pdf en_US
dc.language.iso eng es_ES
dc.publisher Copernicus Publications es_ES
dc.rights Atribución 3.0 España *
dc.rights.uri http://creativecommons.org/licenses/by/3.0/es/ *
dc.subject Radiación ultravioleta es_ES
dc.subject Piel humana es_ES
dc.subject Espectrorradiómetro es_ES
dc.subject Proyecto Europeo EMRP ENV03 es_ES
dc.subject World Radiation Center es_ES
dc.subject Ultraviolet radiation es_ES
dc.subject Human skin es_ES
dc.subject Spectroradiometers es_ES
dc.subject European EMRP ENV03 project es_ES
dc.title Quality assessment of solar UV irradiance measured with array spectroradiometers es_ES
dc.type article es_ES
dc.description.version peerReviewed es_ES
europeana.type TEXT en_US
dc.rights.accessRights openAccess es_ES
dc.subject.unesco 2209.22 Radiación Ultravioleta es_ES
dc.subject.unesco 2202.06 Radiación Infrarroja, Visible y Ultravioleta es_ES
dc.subject.unesco 2501.09 Radiactividad Atmosférica es_ES
europeana.dataProvider Universidad de Extremadura. España es_ES
dc.identifier.bibliographicCitation Egli, L., Gröbner, J., Hülsen, G., Bachmann, L., Blumthaler, M., Dubard, J., Khazova, M., Kift, R., Hoogendijk, K., Serrano, A., Smedley, A., and Vilaplana, J.-M.: Quality assessment of solar UV irradiance measured with array spectroradiometers, Atmos. Meas. Tech., 9, 1553-1567, https://doi.org/10.5194/amt-9-1553-2016, 2016 es_ES
dc.type.version publishedVersion es_ES
dc.contributor.affiliation Physikalisch Meteorologisches Observatorium and World Radiation Center (PMOD/WRC), Davos, Switzerland es_ES
dc.contributor.affiliation Universidade de São Paulo. Brasil pt_PT
dc.contributor.affiliation Medical University of Innsbruck. Austria
dc.contributor.affiliation Laboratoire national de métrologie et d’essais LNE, Paris, France
dc.contributor.affiliation Public Health England, Chilton, UK
dc.contributor.affiliation University of Manchester. UK
dc.contributor.affiliation Universidad de Extremadura. Departamento de Física
dc.contributor.affiliation Instituto Nacional de Técnica Aeroespacial – INTA
dc.relation.publisherversion https://www.atmos-meas-tech.net/9/1553/2016/amt-9-1553-2016.html es_ES
dc.relation.publisherversion https://doi.org/10.5194/amt-9-1553-2016 es_ES
dc.identifier.doi 10.5194/amt-9-1553-2016
dc.identifier.publicationtitle Atmospheric measurement techniques es_ES
dc.identifier.publicationissue 4 es_ES
dc.identifier.publicationfirstpage 1553 es_ES
dc.identifier.publicationlastpage 1567 es_ES
dc.identifier.publicationvolume 9 es_ES


Files in this item

Files Size Format View
amt_9_1553_2016.pdf 2.088Mb PDF View  Thumbnail

The following license files are associated with this item:

This item appears in the following Collection(s)

Show simple item record

Atribución 3.0 España Except where otherwise noted, this item's license is described as Atribución 3.0 España

Search DSpace


Browse

My Account

Statistics

Help

Redes sociales