Identificador persistente para citar o vincular este elemento: http://hdl.handle.net/10662/8264
Títulos: Short-, intermediate-, and long-term changes in basophil reactivity induced by venom immunotherapy
Autores/as: Rodríguez Trabado, Ana
Cámara Hijón, Carmen
Ramos Cantariño, Alfonso
Romero Chala, Silvia
García Trujillo, José Antonio
Fernández Pereira, Luis Miguel
Palabras clave: Activación;Basófilo;Veneno;Inmunoterapia;CD63;Activation;Basophil;Venom;Immunotherapy
Fecha de publicación: 2016
Editor/a: The Korean Academy of Asthma, Allergy and Clinical Immunology
Resumen: PURPOSE: The basophil activation test (BAT) has been used to monitor venom immunotherapy (VIT) due to its high specificity. A previous study has reported a good correlation between a significant decrease in basophil activation during 5 years of VIT and clinical protection assessed by sting challenge. The following prospective study was performed to examine changes in basophil reactivity over a complete VIT period of 5 years. METHODS: BAT in a dose-response curve was studied prospectively in 10 hymenoptera venom-allergic patients over 5 years of VIT. BAT was performed at the time of diagnosis, 1 month after finishing the VIT build-up phase, and 3, 6, 12, 24, and 60 months after beginning treatment. The repeated measures ANOVA was applied to evaluate basophil activation changes throughout VIT. A cross-sectional study was also performed in 6 patients who received treatment for more than 3 years, and in another 12 patients who followed immunotherapy for at least 5 years. RESULTS: An early activation decrease was observed during the first 3 months of treatment, compared to pre-treatment values. This activation decrease was not maintained 6 to 18 months after treatment, but was observed again after 2 years of treatment, and maintained until the completion of the 5-year immunotherapy period. In cross-sectional analysis, the 6 patients who received treatment for 3 years, and 9 of the 12 patients who received treatment for 5 years, had negative BAT results. Three patients in this last group had positive BAT results and 2 patients had systemic reactions after field stings. CONCLUSIONS: BAT appears to be an optimal non-invasive test for close monitoring of VIT.
URI: http://hdl.handle.net/10662/8264
ISSN: 2092-7355
DOI: 10.4168/aair.2016.8.5.412
Colección:DMATE - Artículos

Archivos
Archivo Descripción TamañoFormato 
aair_2016_8_5_412.pdf321,87 kBAdobe PDFDescargar


Este elemento está sujeto a una licencia Licencia Creative Commons Creative Commons