Please use this identifier to cite or link to this item: http://hdl.handle.net/10662/12397
Full metadata record
DC FieldValueLanguage
dc.contributor.authorOrtiz Coder, Pedro-
dc.contributor.authorSánchez Ríos, Alonso-
dc.date.accessioned2021-07-21T11:19:10Z-
dc.date.available2021-07-21T11:19:10Z-
dc.date.issued2019-
dc.identifier.urihttp://hdl.handle.net/10662/12397-
dc.description.abstractLos modelos tridimensionales (3D) se utilizan ampliamente en aplicaciones clínicas, geo-ciencias la conservación del patrimonio cultural y la ingeniería; esto, junto con nuevas necesidades emergentes como el modelado de información de edificios (BIM) desarrollan nuevas técnicas y dispositivos de captura de datos con un bajo coste y una curva de aprendizaje reducida que permiten su empleo a usuarios no especializados. Este trabajo presenta un sencillo dispositivo de auto-ensamblaje para la captura de datos de nubes de puntos 3D con un precio base estimado precio base inferior a 2500 €; además, se describe un flujo de trabajo para los cálculos que incluye un sistema Visual SLAM-fotogramétrico de hilo que se ha implementado en C++. Otro objetivo de este trabajo es validar el sistema propuesto en entornos de trabajo BIM. Para conseguirlo, en pruebas de pruebas en exteriores, se obtuvieron varias nubes de puntos 3D y las coordenadas de 40 puntos de este dispositivo, con distancias de captura de datos que oscilaban entre 5 y 20 m. Posteriormente, se compararon comparadas con las coordenadas de los mismos objetivos medidas por una estación total. Los errores de distancia media euclidiana y el error cuadrático medio (RMSE) oscilaron entre 12-46 mm y 8-33 mm respectivamente, en función de la distancia de captura de datos (5-20 m). Además, el sistema propuesto se comparó con una metodología fotogramétrica comúnmente utilizada basada en el software Agisoft Metashape. Los resultados obtenidos demuestran que el sistema propuesto Los resultados obtenidos demuestran que el sistema propuesto satisface (en cada caso) las tolerancias de "nivel 1" (51 mm) y "nivel 2" (13 mm) para la adquisición de nubes de puntos en el diseño urbano y documentación histórica, según la Guía BIM para la obtención de imágenes en 3D (Servicios Generales de los Estados Unidos).es_ES
dc.description.abstractThree Dimensional (3D) models are widely used in clinical applications, geosciences, cultural heritage preservation, and engineering; this, together with new emerging needs such as building information modeling (BIM) develop new data capture techniques and devices with a low cost and reduced learning curve that allow for non-specialized users to employ it. This paper presents a simple, self-assembly device for 3D point clouds data capture with an estimated base price under €2500; furthermore, a workflow for the calculations is described that includes a Visual SLAM-photogrammetric threaded algorithm that has been implemented in C++. Another purpose of this work is to validate the proposed system in BIM working environments. To achieve it, in outdoor tests, several 3D point clouds were obtained and the coordinates of 40 points were obtained by means of this device, with data capture distances ranging between 5 to 20 m. Subsequently, those were compared to the coordinates of the same targets measured by a total station. The Euclidean average distance errors and root mean square errors (RMSEs) ranging between 12–46 mm and 8–33 mm respectively, depending on the data capture distance (5–20 m). Furthermore, the proposed system was compared with a commonly used photogrammetric methodology based on Agisoft Metashape software. The results obtained demonstrate that the proposed system satisfies (in each case) the tolerances of ‘level 1’ (51 mm) and ‘level 2’ (13 mm) for point cloud acquisition in urban design and historic documentation, according to the BIM Guide for 3D Imaging (U.S. General Services).es_ES
dc.format.extent17 p.es_ES
dc.format.mimetypeapplication/pdfen_US
dc.language.isoenges_ES
dc.rightsAttribution 4.0 International*
dc.rights.urihttp://creativecommons.org/licenses/by/4.0/*
dc.subjectDispositivo de autoensamblajees_ES
dc.subjectNubes de puntos 3Des_ES
dc.subjectAnálisis de precisiónes_ES
dc.subjectVSLAM-Algoritmo fotogramétricoes_ES
dc.subjectSistema cartográfico móvil portátiles_ES
dc.subjectDispositivo de bajo costees_ES
dc.subjectBIMes_ES
dc.subjectSelf-assembly devicees_ES
dc.subject3D point cloudses_ES
dc.subjectAccuracy analysises_ES
dc.subjectVSLAM-photogrammetric algorithmes_ES
dc.subjectPortable mobile mapping systemes_ES
dc.subjectLow-cost devicees_ES
dc.titleA self-assembly portable mobile mapping system for archeological reconstruction based on VSLAM-Photogrammetric algorithmes_ES
dc.typearticlees_ES
dc.description.versionpeerReviewedes_ES
europeana.typeTEXTen_US
dc.rights.accessRightsopenAccesses_ES
dc.subject.unesco2209.18 Fotometríaes_ES
dc.subject.unesco3305.01 Diseño Arquitectónicoes_ES
europeana.dataProviderUniversidad de Extremadura. Españaes_ES
dc.identifier.bibliographicCitationOrtiz-Coder, Pedro, and Alonso Sánchez-Ríos (2019). A Self-Assembly Portable Mobile Mapping System for Archeological Reconstruction Based on VSLAM-Photogrammetric Algorithm. Sensors [online]. 12 September 2019. Vol. 19, no. 18, p. 3952. DOI 10.3390/s19183952.es_ES
dc.type.versionpublishedVersiones_ES
dc.contributor.affiliationUniversidad de Extremadura. Departamento de Expresión Gráficaes_ES
dc.relation.publisherversionhttps://www.mdpi.com/1424-8220/19/18/3952es_ES
dc.relation.publisherversionhttps://doi.org/10.3390/s19183952es_ES
dc.identifier.doi10.3390/s19183952-
dc.identifier.publicationtitleSensorses_ES
dc.identifier.publicationissue18es_ES
dc.identifier.publicationfirstpage1es_ES
dc.identifier.publicationlastpage17es_ES
dc.identifier.publicationvolume19, 3952es_ES
dc.identifier.e-issn1424-8220-
Appears in Collections:DEXGR - Artículos

Files in This Item:
File Description SizeFormat 
s19183952.pdf2,7 MBAdobe PDFView/Open


This item is licensed under a Creative Commons License Creative Commons