Títulos: An automated blood pressure display for self-measurement in patients with chronic kidney disease (iHealth Track): Device validation study
Autores/as: Mazoteras Pardo, Victoria
Becerro de Bengoa Vallejo, Ricardo
Losa Iglesias, Marta Elena
López López, Daniel
Calvo Lobo, César
Rodríguez Sanz, David
Martínez Jiménez, Eva María
Palomo López, Patricia
Palabras clave: iHealth Track;International Protocol;Heart rate;Blood pressure;Validation;Validación;Protocolo Internacional;Presión arterial;Ritmo cardiaco
Fecha de publicación: 2020
Editor/a: JMIR Publications
Resumen: Background: Hypertension is a global public health issue and is closely related to chronic kidney disorder (CKD). In people with CKD, strict monitoring of blood pressure is an important part of therapy. Objective: The aim of this research was to validate the iHealth Track blood pressure monitoring device for patients with CKD according to the European Society of Hypertension International Protocol 2010 (ESH-IP2). Methods: In total, 33 patients who received hemodialysis in Plasencia participated in the study. There were 9 successive measurements made, which conformed to the ESH-IP2. We calculated the differences between the standard reference device (Omron M3 Intellisense) and the test device (iHealth Track) for blood pressure and heart rate values. For 99 total comparisons of paired measurements, we classified differences into various categories (≤5 mmHg, ≤10 mmHg, and ≤15 mmHg for blood pressure; ≤3, ≤5, and ≤8 beats per minute for heart rate). Results: In 90 of 99 systolic blood pressure and 89 of 99 diastolic blood pressure comparisons between the devices, measurement differences were within 5 mmHg. In 81 of 99 heart rate comparisons between the devices, measurement differences were within 3 beats per minute. The mean differences between the test and reference standard measurements were 3.27 (SD 2.99) mmHg for systolic blood pressure, 3.59 (SD 4.55) mmHg for diastolic blood pressure, and 2.18 (SD 2.75) beats per minute for heart rate. We also observed that for both systolic and diastolic blood pressure, 31 of 33 participants had at least two of three comparisons between the devices with measurement differences less than 5 mmHg. For heart rate, 28 of 33 patients had at least two of three comparisons between the devices with measurement differences less than 3 beats per minute. Conclusions: To our knowledge, this is the first study to show that iHealth Track meets the requirements of the ESH-IP2 in patients with CKD. Therefore, the iHealth Track is suitable for use in renal patients.
URI: http://hdl.handle.net/10662/14683
DOI: 10.2196/14702