Identificador persistente para citar o vincular este elemento:
http://hdl.handle.net/10662/19236
Títulos: | The influence of microphone location on results of urban noise measurements |
Autores/as: | Montes González, David Barrigón Morillas, Juan Miguel Rey Gozalo, Guillermo |
Palabras clave: | Ubicación del micrófono;Mediciones del ruido urbano;Normas sobre ruido ambiental;Microphone location;Urban noise measurements;Environmental noise standards |
Fecha de publicación: | 2015 |
Editor/a: | Elsevier |
Resumen: | A la hora de realizar mediciones acústicas para elaborar un mapa de ruido urbano, se suele tomar como referencia la norma internacional norma internacional ISO 1996. Sin embargo, esta norma no determina el lugar preciso donde debemos colocar el equipo de medición. En cambio, en algunos la norma ofrece correcciones del nivel de presión sonora medido para garantizar la reproducibilidad y comparabilidad de los resultados. y comparabilidad de los resultados. En este trabajo hemos realizado mediciones simultáneas con dos sonómetros para estudiar el efecto de variar la ubicación del equipo de medición en cuanto a su altura y a la distancia a la que se encuentra. Los resultados indican la necesidad de aplicar algunas correcciones debidas a reflexiones sobre la fachada con valores inferiores a los recomendados por la norma. Además, se ha visto la necesidad de realizar correcciones por la distancia a la fuente. Las discrepancias entre la norma y los resultados podrían explicarse por la existencia de efectos de apantallamiento efectos de apantallamiento asociados a los carriles de aparcamiento. When carrying out acoustical measurements in order to construct an urban noise map, the ISO 1996 international standard is usually taken as a reference. However, this standard does not determine the precise location where we should place the measuring equipment. Instead, in some cases the standard offers corrections for the measured sound pressure level to assure reproducibility and comparability in the results. In this paper, we have carried out simultaneous measurements with two sound-level meters to study the effect of varying the location of the measuring equipment in terms of its height and the distance to the rear façade.The results indicate the need to apply some corrections due to reflexions on the façade with lower values than those recommended by the standard. In addition, it has been found necessary to make corrections for the distance to the source. Discrepancies between the standard and the results could be explained by the existence of screening effects associated with the parking lanes. |
Descripción: | Publicado en: Applied Acoustics, Vol. 90, 64-73. ISSN 0003-682X. https://doi.org/10.1016/j.apacoust.2014.11.001 |
URI: | http://hdl.handle.net/10662/19236 |
ISSN: | 0003-682X |
DOI: | 10.1016/j.apacoust.2014.11.001 |
Colección: | DFIAP - Artículos |
Archivos
Archivo | Descripción | Tamaño | Formato | |
---|---|---|---|---|
j_apacoust_2014_11_001_AMM.pdf | 1,39 MB | Adobe PDF | Descargar |
Este elemento está sujeto a una licencia Licencia Creative Commons