Identificador persistente para citar o vincular este elemento: http://hdl.handle.net/10662/22061
Títulos: Modeling the erythemal surface diffuse irradiance fraction for Badajoz, Spain
Autores/as: Sánchez Hernández, Guadalupe
Serrano Pérez, Antonio
Cancillo Fernández, María Luisa
Palabras clave: Erythemal radiation;Radiación eritemática;Diffuse irradiance;Irradiancia difusa;Modeling;Modelización
Fecha de publicación: 2017
Editor/a: Copernicus Gesellschaft MBH
Resumen: A pesar de su importante papel en la salud humana y en numerosos procesos biológicos, la componente difusa de la irradiancia ultravioleta eritemática (UVER) apenas se mide en estaciones radiométricas estándar y, por tanto, es necesario realizar una estimación de la misma. Este estudio propone y compara 10 modelos empíricos para estimar la fracción difusa de UVER. Estos modelos se inspiran en expresiones matemáticas utilizadas originalmente para estimar la fracción difusa total, pero, en este estudio, se adaptan al caso UVER y se contrastan con medidas experimentales. Además de adaptar al rango UVER las distintas variables independientes que intervienen en estos modelos, se ha añadido la columna de ozono total para tener en cuenta su fuerte impacto en la atenuación de la radiación ultravioleta. Los modelos propuestos se ajustan a las mediciones experimentales y se validan frente a un subconjunto independiente. El modelo con mejores resultados (RAU3) se basa en un modelo propuesto por Ruiz-Arias et al. (2010) y muestra valores de r2 iguales a 0,91 y error cuadrático medio relativo (rRMSE) iguales a 6,1 %. El rendimiento alcanzado por este modelo totalmente empírico es mejor que los obtenidos por enfoques semiempíricos anteriores y, por lo tanto, no necesita información adicional de otros modelos físicos. Este estudio amplía las investigaciones anteriores al rango ultravioleta y proporciona modelos empíricos fiables para estimar con precisión la fracción difusa del UVER.
Despite its important role on the human health and numerous biological processes, the diffuse component of the erythemal ultraviolet irradiance (UVER) is scarcely measured at standard radiometric stations and therefore needs to be estimated. This study proposes and compares 10 empirical models to estimate the UVER diffuse fraction. These models are inspired from mathematical expressions originally used to estimate total diffuse fraction, but, in this study, they are applied to the UVER case and tested against experimental measurements. In addition to adapting to the UVER range the various independent variables involved in these models, the total ozone column has been added in order to account for its strong impact on the attenuation of ultraviolet radiation. The proposed models are fitted to experimental measurements and validated against an independent subset. The best-performing model (RAU3) is based on a model proposed by Ruiz-Arias et al. (2010) and shows values of r 2 equal to 0.91 and relative root-mean-square error (rRMSE) equal to 6.1 %. The performance achieved by this entirely empirical model is better than those obtained by previous semi-empirical approaches and therefore needs no additional information from other physically based models. This study expands on previous research to the ultraviolet range and provides reliable empirical models to accurately estimate the UVER diffuse fraction.
URI: http://hdl.handle.net/10662/22061
ISSN: 1680-7316
DOI: 10.5194/acp-17-12697-2017
Colección:DFSCA - Artículos

Archivos
Archivo Descripción TamañoFormato 
acp-17-12697-2017.pdf739,92 kBAdobe PDFDescargar


Este elemento está sujeto a una licencia Licencia Creative Commons Creative Commons