Identificador persistente para citar o vincular este elemento: http://hdl.handle.net/10662/23168
Títulos: Electrical and thermal energy in private hospitals: consumption indicators focused on healthcare activity
Autores/as: García Sanz-Calcedo, Justo
Gómez Chaparro, Miguel
Sánchez-Barroso Moreno, Gonzalo
Palabras clave: Centro sanitario;Hospital;Consumo energético;Ingeniería sanitaria;Indicadores clave de rendimiento;Healthcare centre;Energy consumption;Healthcare engineering;Key performance indicator (KPIs)
Fecha de publicación: 2019
Editor/a: Elsevier
Resumen: Mejorar la eficiencia energética de los edificios sanitarios es un reto importante en este sector de la ingeniería. Sin embargo, el indicador de consumo energético comúnmente utilizado en los hospitales públicos (kWh por cama) no tiene en cuenta la actividad asistencial que se desarrolla en estos edificios. Se ha realizado un análisis del consumo anual de energía térmica y eléctrica en 13 hospitales privados españoles entre 2008 y 2017 con la intención de encontrar indicadores de consumo energético basados en la actividad asistencial que se desarrolla en un hospital. Todos los edificios objeto de estudio habían sido construidos o rehabilitados entre 1990 y 2013, con una superficie útil y número de camas de 2314-23.888m² y de 20-264 camas. Los resultados mostraron una alta correlación entre el consumo medio anual de energía y el número de altas anuales, el número de actuaciones de urgencia y el número de estancias de hospitalización. También se observaron correlaciones estadísticas similares entre la superficie útil y el número de empleados. Sin embargo, se detectó una baja correlación entre el consumo energético y el número de camas. Además, se estudió el número de cirugías anuales, pruebas de laboratorio, partos y endoscopias, comprobándose que también están directamente relacionados con el consumo energético anual por miembro del personal. Por último, en función de la actividad asistencial, se proponen indicadores de consumo energético final.
Improving energy efficiency in healthcare buildings is a major challenge in this sector of engineering. However, the energy consumption indicator commonly used in public hospitals (kWh per bed) does not take into account the healthcare activity carried out in these buildings. An analysis of the annual thermal and electrical energy consumption was performed in 13 Spanish private hospitals between 2008 and 2017 intending to find energy consumption indicators based on the healthcare activity that takes place in a hospital. All the buildings under study had been either built or retrofitted between 1990 and 2013, with useful floor area and number of beds 2314-23,888m² and 20–264 beds. The results showed a high correlation between the average annual energy consumption and the number of annual discharges, number of emergencies actions and number of hospitalization stays. Similar statistical correlations were also observed between useful floor area and number of staff. However, a low correlation was detected between energy consumption and number of beds. Additionally, number of annual surgeries, laboratory tests, births, and endoscopies, were studied, proving that they are also directly related with the annual energy consumption per staff member. Finally, based on the healthcare activity, final energy consumption indicators are proposed.
Descripción: Publicado en: Sustainable Cities and Society, Volume 47, May 2019, 101482; con DOI: https://doi.org/10.1016/j.scs.2019.101482
URI: http://hdl.handle.net/10662/23168
ISSN: 2210-6707
DOI: 10.1016/j.scs.2019.101482
Colección:DEXGR - Artículos

Archivos
Archivo Descripción TamañoFormato 
j_scs_2019_101482_AAM.pdf370,64 kBAdobe PDFDescargar


Este elemento está sujeto a una licencia Licencia Creative Commons Creative Commons