Abstract: El objetivo de este documento es cuantificar el consumo medio anual de agua en 13 hospitales públicos de Extremadura (España). Se llevó a cabo un estudio analítico para reducir la demanda de agua de 2010 a 2014 en los hospitales mencionados. El estudio concluyó que, para determinar el consumo promedio anual de agua, una proporción fija no es la herramienta adecuada. En su lugar, se debe utilizar un tipo paramétrico relacionado con el área de la superficie construida y / o la cantidad de camas por hospital. El consumo promedio anual de agua fría para consumo humano (CWHC) fue de 262.82 m3 (102.10) por cama y 1.65 m3 (0.46) por área de superficie construida. El consumo anual promedio de agua caliente doméstica (ACS) fue de 92.96 m3 (35.72) por cama y 0.59 m3 (0.18) por superficie construida. La relación entre ACS y CWHC fue de 35,62% (5,53). El período de tiempo de mayor demanda fue entre las 12 p.m. y 6 p.m. Considerando B como el número de camas de hospital y S su área de superficie construida, para calcular el promedio anual de agua fría para consumo humano en un hospital, se debe usar la ecuación 165B + 12,100 (m3) o 1.568S + 2400 (m3). De manera similar, en términos de agua caliente doméstica, el consumo promedio anual en m3 corresponde a 53.65B + 5170 (m3) o 0.53S + 1400 (m3).
The aim of this paper is to quantity the annual average consumption of water in 13 public hospitals in Extremadura (Spain). An analytical study in order to reduce water demand was conducted from 2010 to 2014 in the above-mentioned hospitals. The study concluded that, in order to determine the average annual water consumption, a fixed ratio is not the appropriate tool. A parametric type related to the built surface area and/or number of beds by hospital should be used instead. The average annual consumption of cold water for human consumption (CWHC) was 262.82 m3 (102.10) per bed and 1.65 m3 (0.46) per built surface area. The mean annual consumption of domestic hot water (DHW) was 92.96 m3 (35.72) per bed and 0.59 m3 (0.18) per built surface area. The ratio between DHW and CWHC was 35.62% (5.53). The time period of greatest demand was between 12 p.m. and 6 p.m. Considering B as the number of hospital beds and S its built surface area, to calculate the average annual cold water for human consumption in a hospital, the equation 165B + 12,100 (m3) or 1.568S + 2400 (m3) should be used. Similarly, in terms of hot domestic water, the average annual consumption in m3 corresponds to either 53.65B + 5170 (m3) or 0.53S + 1400 (m3).
URI: http://hdl.handle.net/10662/8403
ISSN: 1996-1073
DOI: 10.3390/en10040479
Appears in Collections:DIMEM - Artículos

Files in This Item:
File Description SizeFormat 
en10040479.pdf1,22 MBAdobe PDFView/Open


This item is licensed under a Creative Commons License Creative Commons