dc.description.abstractLa principal causa de muerte en el mundo se relaciona con patologías del sistema cardiovascular. La cirugía convencional mediante el uso de injertos vasculares autólogos es la principal opción quirúrgica para el tratamiento de estas patologías. Sin embargo, en determinados pacientes, puede no ser posible utilizar estos injertos. Por este motivo, los injertos vasculares basados en ingeniería tisular resultan prometedores como tratamiento quirúrgico. Esta tesis doctoral tiene como objetivo el análisis y validación de las propiedades fisicoquímicas y biológicas de materiales destinados al diseño de injertos vasculares de ingeniería tisular. Para ello, el presente trabajo se ha divido en dos bloques temáticos. El primer bloque se centra en el estado actual del desarrollo de los injertos vasculares de ingeniería de tejidos. El segundo bloque aborda la fabricación y análisis de estructuras básicas diseñadas con fibroína de seda y fluoruro de polivinilideno mediante diversas técnicas de ingeniería tisular. Estos estudios aportaron información de las características fisicoquímicas y biológicas de los polímeros, cuyos resultados sirvieron para comprobar si son óptimos para el diseño de injertos vasculares, así como hallar la mejor metodología para su desarrollo. En definitiva, la presente tesis doctoral ha permitido la validación de los polímeros de fibroína de seda y fluoruro de polivinilideno para su uso en el diseño de injertos vasculares de ingeniería tisular. Hemos obtenido unos resultados prometedores con la tecnología del electrohilado, estableciendo una línea de investigación en el ámbito de materiales e ingeniería tisular.es_ES
dc.description.abstractCardiovascular diseases are the leading causes of death worldwide. Conventional surgery is the main surgical option for the treatment of these diseases through the use of autologous vascular grafts. However, in certain patients, the use of these grafts is not possible. In this situation, tissue-engineered vascular grafts are a promising therapeutic option. The aim of this PhD thesis is to analyze and validate the physicochemical and biological properties of materials that can be used for the development of tissue-engineered vascular grafts. This research has been divided into several chapters. The first chapter addresses the current state of development of tissue-engineered vascular grafts. The second chapter focuses on the manufacture and analysis of basic architectures designed with silk fibroin and poly(vinylidene fluoride) using various tissue engineering techniques. These studies provided information on the physicochemical and biological properties of the polymers, the results of which were used to determine they are optimal for vascular graft engineering, and select the best manufacturing method. In conclusion, we have validated silk fibroin and poly(vinylidene fluoride) polymers for the development of tissue-engineered vascular grafts. Promising results have been obtained with electrospinning technology, establishing a new branch of research in the field of materials and tissue engineering.es_ES
dc.description.sponsorshipEsta tesis doctoral ha sido financiada parcialmente a través de la ayuda PD18077 para la financiación de contratos predoctorales y de las ayudas GR18199 y GR21201 a Grupos de Investigación Catalogados, todas de la Consejería de Economía, Ciencia y Agenda Digital de la Junta de Extremadura/FSE y FEDER.es_ES
dc.format.extent133 p.es_ES
dc.format.mimetypeapplication/pdfen_US
dc.language.isospaes_ES
dc.rightsAttribution-NonCommercial-NoDerivatives 4.0 International*
dc.rights.urihttp://creativecommons.org/licenses/by-nc-nd/4.0/*
dc.subjectInjerto vasculares_ES
dc.subjectIngeniería de tejidoses_ES
dc.subjectMaterialeses_ES
dc.subjectVascular graftes_ES
dc.subjectTissue engineeringes_ES
dc.subjectMaterialses_ES
dc.titleAnálisis y validación de materiales destinados al diseño de injertos vasculares de ingeniería tisulares_ES
dc.typedoctoralThesises_ES
europeana.typeTEXTen_US
dc.rights.accessRightsopenAccesses_ES
dc.subject.unesco3213.17 Cirugía Vasculares_ES
dc.subject.unesco3312.08 Propiedades de Los Materialeses_ES
europeana.dataProviderUniversidad de Extremadura. Españaes_ES
dc.date.exposureEnd2023-05-04-
dc.date.exposureStart2023-04-20-
dc.identifier.orcid0000-0002-2106-3524es_ES
dc.identifier.orcid0000-0003-2138-988Xes_ES
dc.identifier.orcid0000-0003-1740-7029es_ES
Colección:Tesis doctorales

Archivos
Archivo Descripción TamañoFormato 
TDUEX_2023_Duran_Rey.pdf8,97 MBAdobe PDFDescargar


Este elemento está sujeto a una licencia Licencia Creative Commons Creative Commons